12 V hydraulic power unit: installation, maintenance and troubleshooting
How to install, fill, start and look after the 12 V DC hydraulic power unit of Debon PW tippers, and what to check when it fails.
PW0 · PW1.2 · PW2.4 · PW3.0 · PW3.3 · PW3.6
At a glance
- Supply voltage
- 12 V DC
- Motor power
- 1.6 kW
- Tank capacity
- 8 L (PW0, PW1.2, PW2.4, PW3.0, PW3.3) / 10 L (PW3.6)
- Mounting bolts
- 2 x M10, tightened to 50 Nm
- Hydraulic oil
- ISO VG 32, 46 or 68 depending on ambient temperature
- Oil filtration
- 10-30 µm
- Operating temperature
- -20 °C to +80 °C
- Motor duty cycle
- Max. 2 minutes running, then at least 30 minutes rest
- Minimum battery voltage
- Below 10 V the electrical system can be damaged
- Installation must be done by qualified personnel.
- Disconnect the cables from the battery before connecting them to the power unit.
- Never run the power unit without oil.
- Do not run the motor for more than 2 minutes at a time; let it rest at least 30 minutes before running it again.
- Keep the hydraulic oil clean: dirty oil damages the valves and the pump.
- Air in the system causes uneven, noisy operation and can make the cylinder drop suddenly.
- Protect the power unit from corrosive environments.
Before you start
- Mounting position
- The unit can be mounted horizontally or vertically (tank down), depending on the tank type.
- The body will not come down
- Turn the manual unloading valve anticlockwise: the body lowers immediately. Not all solenoid valves have this manual valve.
- Remote control
- The remote control is already wired at the factory: you only need to connect the battery to the motor and the motor starter.
Something wrong?
Open the problem you see to get the possible causes and what to do.
The pump does not draw oil, or works unevenly4 possible causes
- Oil level too low
Top up the oil to the required level.
- Oil too viscous
Use an oil of suitable viscosity.
- Suction filter blocked
Clean or replace the suction filter.
- Solenoid valve blocked
Clean the solenoid valve and clean the oil.
The body drops unevenly2 possible causes
- Solenoid valve blocked
Clean the solenoid valve and change the oil.
- Check valve blocked
Clean the check valve.
The motor runs but no oil is delivered1 possible cause
- Filter dirty or oil contaminated
Clean the filter or change the oil.
The motor does not run3 possible causes
- Battery low
Check the battery charge.
- Remote control fault
Check the remote control.
- Motor starter (solenoid switch) fault
Check the solenoid switch of the motor.
The body does not come down3 possible causes
- Solenoid valve blocked
Check and clean the solenoid valve.
- Remote control switch fault
Check the remote control switch.
- Valve does not open
Turn the manual unloading valve anticlockwise to lower the body (if your valve has one).
Check before every trip
- Motor wired correctly, connections tight, correct voltage
- Oil level in the tank correct
- Relief valve setting checked with a pressure gauge in the outlet line
- No external leaks at the cylinder, hoses or power unit
- Battery fully charged
Maintenance
| What | When |
|---|---|
| First oil change | After the first 100 working hours |
| Oil change | At least once a year |
| Run the unit (oil tank kept full) | Once a week if the trailer is not used for a long time |
Steps
0 / 7 done
Disconnect the battery
Make sure the battery cables are disconnected from the battery before you connect them to the power unit.
Mount the unit
Fit the power unit in its position and tighten the 2 M10 mounting bolts to 50 Nm.
Connect the cables
Connect the battery positive (+) cable to the free (+) terminal of the motor starter, and the battery negative (-) cable to the free (-) terminal of the motor. Make sure the black earth cable of the starter is also connected to this negative terminal.
Protect the supply
Fit a fuse of suitable rating on the positive cable between the battery and the power unit, and fit a battery isolation switch.
Clean before first use
Clean the oil tank, the hydraulic hoses and the fittings before operating the unit.
Fill with oil
Fill the tank with clean, recommended hydraulic oil. Watch the oil level if the cylinder is already extended and filled with oil.
First start
Check that the battery is charged, then run the unit. If no oil flows, bleed the air at the highest point of the system with the system under pressure.