User & maintenance manual

12 V hydraulic power unit: installation, maintenance and troubleshooting

How to install, fill, start and look after the 12 V DC hydraulic power unit of Debon PW tippers, and what to check when it fails.

Debon TrailersPW0 · PW1.2 · PW2.4 · PW3.0 · PW3.3 · PW3.6

At a glance

Supply voltage
12 V DC
Motor power
1.6 kW
Tank capacity
8 L (PW0, PW1.2, PW2.4, PW3.0, PW3.3) / 10 L (PW3.6)
Mounting bolts
2 x M10, tightened to 50 Nm
Hydraulic oil
ISO VG 32, 46 or 68 depending on ambient temperature
Oil filtration
10-30 µm
Operating temperature
-20 °C to +80 °C
Motor duty cycle
Max. 2 minutes running, then at least 30 minutes rest
Minimum battery voltage
Below 10 V the electrical system can be damaged
Safety first
  • Installation must be done by qualified personnel.
  • Disconnect the cables from the battery before connecting them to the power unit.
  • Never run the power unit without oil.
  • Do not run the motor for more than 2 minutes at a time; let it rest at least 30 minutes before running it again.
  • Keep the hydraulic oil clean: dirty oil damages the valves and the pump.
  • Air in the system causes uneven, noisy operation and can make the cylinder drop suddenly.
  • Protect the power unit from corrosive environments.

Before you start

Mounting position
The unit can be mounted horizontally or vertically (tank down), depending on the tank type.
The body will not come down
Turn the manual unloading valve anticlockwise: the body lowers immediately. Not all solenoid valves have this manual valve.
Remote control
The remote control is already wired at the factory: you only need to connect the battery to the motor and the motor starter.

Something wrong?

Open the problem you see to get the possible causes and what to do.

The pump does not draw oil, or works unevenly4 possible causes
  1. Oil level too low

    Top up the oil to the required level.

  2. Oil too viscous

    Use an oil of suitable viscosity.

  3. Suction filter blocked

    Clean or replace the suction filter.

  4. Solenoid valve blocked

    Clean the solenoid valve and clean the oil.

The body drops unevenly2 possible causes
  1. Solenoid valve blocked

    Clean the solenoid valve and change the oil.

  2. Check valve blocked

    Clean the check valve.

The motor runs but no oil is delivered1 possible cause
  1. Filter dirty or oil contaminated

    Clean the filter or change the oil.

The motor does not run3 possible causes
  1. Battery low

    Check the battery charge.

  2. Remote control fault

    Check the remote control.

  3. Motor starter (solenoid switch) fault

    Check the solenoid switch of the motor.

The body does not come down3 possible causes
  1. Solenoid valve blocked

    Check and clean the solenoid valve.

  2. Remote control switch fault

    Check the remote control switch.

  3. Valve does not open

    Turn the manual unloading valve anticlockwise to lower the body (if your valve has one).

Check before every trip

  • Motor wired correctly, connections tight, correct voltage
  • Oil level in the tank correct
  • Relief valve setting checked with a pressure gauge in the outlet line
  • No external leaks at the cylinder, hoses or power unit
  • Battery fully charged

Maintenance

WhatWhen
First oil changeAfter the first 100 working hours
Oil changeAt least once a year
Run the unit (oil tank kept full)Once a week if the trailer is not used for a long time

Steps

0 / 7 done

  1. Disconnect the battery

    Make sure the battery cables are disconnected from the battery before you connect them to the power unit.

  2. Mount the unit

    Fit the power unit in its position and tighten the 2 M10 mounting bolts to 50 Nm.

  3. Connect the cables

    Connect the battery positive (+) cable to the free (+) terminal of the motor starter, and the battery negative (-) cable to the free (-) terminal of the motor. Make sure the black earth cable of the starter is also connected to this negative terminal.

  4. Protect the supply

    Fit a fuse of suitable rating on the positive cable between the battery and the power unit, and fit a battery isolation switch.

  5. Clean before first use

    Clean the oil tank, the hydraulic hoses and the fittings before operating the unit.

  6. Fill with oil

    Fill the tank with clean, recommended hydraulic oil. Watch the oil level if the cylinder is already extended and filled with oil.

  7. First start

    Check that the battery is charged, then run the unit. If no oil flows, bleed the air at the highest point of the system with the system under pressure.