Assembly instructions

Roof vent

How to fit, use and care for the Fiamma Vent roof vent (39 x 39 cm cut-out) on Gold and Gold XL vans.

Cheval LibertéGold · Gold XL

Safety first
  • Check the roof thickness is compatible before fitting.
  • Make sure the vent will not interfere with roof bars, cables, roof reinforcements or interior cupboards, and that the roof is flat inside and out.
  • Do not modify the product.
  • Never open the vent while driving or in strong wind or rain.
  • Check the vent is properly closed before setting off.
  • Do not walk on the vent cover; clear snow and ice from it.
  • Never clean with alcohol, solvents, abrasives, glass cleaners or all-purpose cleaners.

Before you start

Roof thicker than 5 cm (up to 8.5 cm)
Use the optional Fiamma Extension Vent kit (Ivory 98683-116, White 98683-112).
Crystal cover
Clean with an acrylic glass cleaner and a soft cloth to avoid scratches.

At a glance

Roof cut-out
39 x 39 cm
Roof thickness
3 to 5 cm (up to 8.5 cm with the Extension Vent kit)
Outer frame screws
20 x Ø4.2 x 30 mm, UNI EN ISO 7049 (not supplied)
Inner frame screws
4 x Ø3.5 x 15 mm self-tapping, UNI EN ISO 7049 (not supplied)
Inner frame screw torque
1 Nm
Outer dimensions
45.5 x 45.5 cm
Weight
2.8 kg
Recommended sealant
Sikalastomer-710, Terostat II or Dekalin 1512

Tools you need

  • Tape measure
  • Pencil
  • Jigsaw
  • Sealant gun
  • Screwdriver
  • Waterproof sealant

Drawings

Steps

0 / 6 done

  1. Cut the opening

    Choose the position of the vent and cut a 39 x 39 cm square hole in the roof.

  2. Apply sealant

    Clean the roof area thoroughly. Apply waterproof sealant to the underside of the outer frame.

    Parts: Outer frame (A)

  3. Insert the vent

    Insert the outer part into the opening with the hinges facing the direction of travel. Press the frame lightly onto the roof to spread the sealant evenly.

    Parts: Outer frame (A)

  4. Screw the outer frame

    Fix the outer frame with 20 screws Ø4.2 x 30 mm.

    Parts: 20 screws Ø4.2 x 30 mm

  5. Seal and fit the inner frame

    Seal the whole perimeter of the outer frame, any gaps and all 20 screw heads. Fit the inner frame in the opening with 4 self-tapping screws Ø3.5 x 15 mm.

    Parts: Inner frame (B), screw caps (C), 4 screws Ø3.5 x 15 mm

  6. Remove the protective film

    Peel the protective film off the cover. Do not leave the vent in the sun too long first, or the film becomes hard to remove.